AU Care Agency Employee Identifier [FMM 1]
This identifier profile defines a My Health Record assigned care agency employee (CAE) identifier[1] in an Australian context. A CAE identifier may be issued to an employee of, or person under contracted arrangement with, a care agency who wishes to participate in the My Health Record.
No extensions are used in this profile.
Practitioner with HPI-I, prescriber number, AHPRA registration number, and CAE identifier
The official URL for this profile is:
http://hl7.org.au/fhir/StructureDefinition/au-careagencyemployeeidentifier
This identifier profile defines a care agency employee (CAE) identifier in an Australian context.
This profile builds on Identifier.
This profile was published on 2021-11-05 as a draft by Health Level Seven Australia (Patient Administration WG).
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | I | 0..* | Identifier | Care Agency Employee (CAE) Identifier inv-caei-0: CAE identifier shall be 16 digits inv-caei-1: CAE identifier prefix shall be 900360 inv-caei-2: CAE identifier shall pass the Luhn algorithm check |
type | 1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org.au/CodeSystem/v2-0203 | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: CAEI | |
system | 1..1 | uri | The namespace for the identifier value Fixed Value: http://ns.electronichealth.net.au/id/pcehr/caei/1.0 | |
value | 1..1 | string | CAE identifier Example CAE identifier: 9003600003999997 Max Length: 16 | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | I | 0..* | Identifier | Care Agency Employee (CAE) Identifier inv-caei-0: CAE identifier shall be 16 digits inv-caei-1: CAE identifier prefix shall be 900360 inv-caei-2: CAE identifier shall pass the Luhn algorithm check |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
type | Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org.au/CodeSystem/v2-0203 | |
version | 0..1 | string | Version of the system - if relevant | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: CAEI | |
display | 0..1 | string | Representation defined by the system | |
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |
text | 0..1 | string | Plain text representation of the concept | |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://ns.electronichealth.net.au/id/pcehr/caei/1.0 |
value | Σ | 1..1 | string | CAE identifier Example General: 123456 Example CAE identifier: 9003600003999997 Max Length: 16 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) |
Documentation for this format |
Differential View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | I | 0..* | Identifier | Care Agency Employee (CAE) Identifier inv-caei-0: CAE identifier shall be 16 digits inv-caei-1: CAE identifier prefix shall be 900360 inv-caei-2: CAE identifier shall pass the Luhn algorithm check |
type | 1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org.au/CodeSystem/v2-0203 | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: CAEI | |
system | 1..1 | uri | The namespace for the identifier value Fixed Value: http://ns.electronichealth.net.au/id/pcehr/caei/1.0 | |
value | 1..1 | string | CAE identifier Example CAE identifier: 9003600003999997 Max Length: 16 | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Identifier | I | 0..* | Identifier | Care Agency Employee (CAE) Identifier inv-caei-0: CAE identifier shall be 16 digits inv-caei-1: CAE identifier prefix shall be 900360 inv-caei-2: CAE identifier shall pass the Luhn algorithm check |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |
use | ?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
type | Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
coding | 1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
id | 0..1 | string | Unique id for inter-element referencing | |
extension | 0..* | Extension | Additional content defined by implementations | |
system | 1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org.au/CodeSystem/v2-0203 | |
version | 0..1 | string | Version of the system - if relevant | |
code | 1..1 | code | Symbol in syntax defined by the system Fixed Value: CAEI | |
display | 0..1 | string | Representation defined by the system | |
userSelected | 0..1 | boolean | If this coding was chosen directly by the user | |
text | 0..1 | string | Plain text representation of the concept | |
system | Σ | 1..1 | uri | The namespace for the identifier value Fixed Value: http://ns.electronichealth.net.au/id/pcehr/caei/1.0 |
value | Σ | 1..1 | string | CAE identifier Example General: 123456 Example CAE identifier: 9003600003999997 Max Length: 16 |
period | Σ | 0..1 | Period | Time period when id is/was valid for use |
assigner | Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) |
Documentation for this format |
Downloads: StructureDefinition: (XML, JSON), Schema: XML Schematron
Below is an overview of the required search and read operations.
Summary of Search Criteria for StructureDefinition-au-careagencyemployeeidentifier