This page is part of the Australian Base IG (v1.1.1: AU Base 1.1 on STU3 Draft) based on FHIR R3. The current version which supercedes this version is 1.0.2. For a full list of available versions, see the Directory of published versions
AU Body Height [FMM Level 2]
This profile defines a body height information structure for use in an Australian context that tightens the BodyHeightCode slice, aligning to the proposed R4 Observation Body Height profile.
As per the R4 Vital Signs guidance, a separate profile for Body Length is not supported. This observation may be supplemented with an additional coding element containing the LOINC code 8306-3 -Body height - lying (i.e., body length - typically used for infants).
Note: Known issues with vital signs and observation constraints should be considered when using this profile FHIR R4 has corrections that may be useful12
The official URL for this profile is:
http://hl7.org.au/fhir/StructureDefinition/au-bodyheight
This profile defines a body height information structure for use in an Australian context that tightens the BodyHeightCode slice, aligning to the proposed R4 Observation Body Height profile.
This profile builds on Vital Signs Profile.
This profile was published on Wed Jan 22 10:17:54 AEDT 2020 as a active by Health Level Seven Australia (Orders and Observations WG).
Description of Profiles, Differentials, Snapshots, and how the XML and JSON presentations work.
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | Vital Signs Profile | An observation of body height in an Australian healthcare context | |
code | 1..1 | CodeableConcept | Required body height code | |
coding | 1..* | Coding | Required coding | |
coding:BodyHeightCode | 1..1 | Coding | Body height code | |
system | 1..1 | uri | LOINC coding system | |
code | 1..1 | code | Body height LOINC code | |
Documentation for this format |
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | I | 0..* | Vital Signs Profile | An observation of body height in an Australian healthcare context |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) Max Binding: All Languages | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | Σ | 0..* | Identifier | Business Identifier for observation |
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ProcedureRequest | ReferralRequest) | Fulfills plan, proposal or order |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) |
category | SI | 1..* | CodeableConcept | Classification of type of observation Binding: Observation Category Codes (preferred) vs-4: Must have a category of 'vital-signs' and a code system 'http://hl7.org/fhir/observation-category' |
code | SΣ | 1..1 | CodeableConcept | Required body height code Binding: Vital Signs (extensible) |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
coding | Σ | 1..* | (Slice Definition) | Required coding Slice: Unordered, Open by value:code |
coding:BodyHeightCode | Σ | 1..1 | Coding | Body height code |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
system | Σ | 1..1 | uri | LOINC coding system Fixed Value: http://loinc.org |
version | Σ | 0..1 | string | Version of the system - if relevant |
code | Σ | 1..1 | code | Body height LOINC code Fixed Value: 8302-2 |
display | Σ | 0..1 | string | Representation defined by the system |
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user |
text | Σ | 0..1 | string | Plain text representation of the concept |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what this is about |
context | 0..1 | Reference(Encounter | EpisodeOfCare) | Healthcare event during which this observation is made | |
effective[x] | SΣI | 1..1 | Often just a dateTime for Vital Signs vs-1: Datetime must be at least to day. | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
issued | Σ | 0..1 | instant | Date/Time this was made available |
performer | Σ | 0..* | Reference(Practitioner | Organization | Patient | RelatedPerson) | Who is responsible for the observation |
valueQuantity | SΣI | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: Vital Signs Units (required) |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required) |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣI | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Binding: Body Length Units (required) |
dataAbsentReason | SI | 0..1 | CodeableConcept | Why the result is missing Binding: Observation Value Absent Reason (extensible) |
interpretation | 0..1 | CodeableConcept | High, low, normal, etc. Binding: Observation Interpretation Codes (extensible) | |
comment | 0..1 | string | Comments about result | |
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMED CT Body Structures (example) | |
method | 0..1 | CodeableConcept | How it was done Binding: Observation Methods (example) | |
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |
referenceRange | I | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
low | I | 0..1 | SimpleQuantity | Low Range, if relevant |
high | I | 0..1 | SimpleQuantity | High Range, if relevant |
type | 0..1 | CodeableConcept | Reference range qualifier Binding: Observation Reference Range Meaning Codes (extensible) | |
appliesTo | 0..* | CodeableConcept | Reference range population Binding: Observation Reference Range Applies To Codes (example) | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
related | SΣI | 0..* | BackboneElement | Used when reporting vital signs panel components |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
type | S | 1..1 | code | has-member | derived-from | sequel-to | replaces | qualified-by | interfered-by Binding: ObservationRelationshipType (required) Fixed Value: has-member |
target | S | 1..1 | Reference(VitalSigns) | Resource that is related to this one |
component | SΣI | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: Vital Signs (extensible) |
valueQuantity | SΣ | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: Vital Signs Units (required) |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required) |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣI | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. |
dataAbsentReason | SI | 0..1 | CodeableConcept | Why the component result is missing Binding: Observation Value Absent Reason (extensible) |
interpretation | 0..1 | CodeableConcept | High, low, normal, etc. Binding: Observation Interpretation Codes (extensible) | |
referenceRange | 0..* | Unknown reference to #Observation.referenceRange Provides guide for interpretation of component result | ||
Documentation for this format |
Differential View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | 0..* | Vital Signs Profile | An observation of body height in an Australian healthcare context | |
code | 1..1 | CodeableConcept | Required body height code | |
coding | 1..* | Coding | Required coding | |
coding:BodyHeightCode | 1..1 | Coding | Body height code | |
system | 1..1 | uri | LOINC coding system | |
code | 1..1 | code | Body height LOINC code | |
Documentation for this format |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | I | 0..* | Vital Signs Profile | An observation of body height in an Australian healthcare context |
id | Σ | 0..1 | id | Logical id of this artifact |
meta | Σ | 0..1 | Meta | Metadata about the resource |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created |
language | 0..1 | code | Language of the resource content Binding: Common Languages (extensible) Max Binding: All Languages | |
text | I | 0..1 | Narrative | Text summary of the resource, for human interpretation |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored |
identifier | Σ | 0..* | Identifier | Business Identifier for observation |
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ProcedureRequest | ReferralRequest) | Fulfills plan, proposal or order |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ObservationStatus (required) |
category | SI | 1..* | CodeableConcept | Classification of type of observation Binding: Observation Category Codes (preferred) vs-4: Must have a category of 'vital-signs' and a code system 'http://hl7.org/fhir/observation-category' |
code | SΣ | 1..1 | CodeableConcept | Required body height code Binding: Vital Signs (extensible) |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
coding | Σ | 1..* | (Slice Definition) | Required coding Slice: Unordered, Open by value:code |
coding:BodyHeightCode | Σ | 1..1 | Coding | Body height code |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
system | Σ | 1..1 | uri | LOINC coding system Fixed Value: http://loinc.org |
version | Σ | 0..1 | string | Version of the system - if relevant |
code | Σ | 1..1 | code | Body height LOINC code Fixed Value: 8302-2 |
display | Σ | 0..1 | string | Representation defined by the system |
userSelected | Σ | 0..1 | boolean | If this coding was chosen directly by the user |
text | Σ | 0..1 | string | Plain text representation of the concept |
subject | SΣ | 1..1 | Reference(Patient) | Who and/or what this is about |
context | 0..1 | Reference(Encounter | EpisodeOfCare) | Healthcare event during which this observation is made | |
effective[x] | SΣI | 1..1 | Often just a dateTime for Vital Signs vs-1: Datetime must be at least to day. | |
effectiveDateTime | dateTime | |||
effectivePeriod | Period | |||
issued | Σ | 0..1 | instant | Date/Time this was made available |
performer | Σ | 0..* | Reference(Practitioner | Organization | Patient | RelatedPerson) | Who is responsible for the observation |
valueQuantity | SΣI | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: Vital Signs Units (required) |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required) |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣI | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. Binding: Body Length Units (required) |
dataAbsentReason | SI | 0..1 | CodeableConcept | Why the result is missing Binding: Observation Value Absent Reason (extensible) |
interpretation | 0..1 | CodeableConcept | High, low, normal, etc. Binding: Observation Interpretation Codes (extensible) | |
comment | 0..1 | string | Comments about result | |
bodySite | 0..1 | CodeableConcept | Observed body part Binding: SNOMED CT Body Structures (example) | |
method | 0..1 | CodeableConcept | How it was done Binding: Observation Methods (example) | |
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation | |
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |
referenceRange | I | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
low | I | 0..1 | SimpleQuantity | Low Range, if relevant |
high | I | 0..1 | SimpleQuantity | High Range, if relevant |
type | 0..1 | CodeableConcept | Reference range qualifier Binding: Observation Reference Range Meaning Codes (extensible) | |
appliesTo | 0..* | CodeableConcept | Reference range population Binding: Observation Reference Range Applies To Codes (example) | |
age | 0..1 | Range | Applicable age range, if relevant | |
text | 0..1 | string | Text based reference range in an observation | |
related | SΣI | 0..* | BackboneElement | Used when reporting vital signs panel components |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
type | S | 1..1 | code | has-member | derived-from | sequel-to | replaces | qualified-by | interfered-by Binding: ObservationRelationshipType (required) Fixed Value: has-member |
target | S | 1..1 | Reference(VitalSigns) | Resource that is related to this one |
component | SΣI | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: Vital Signs (extensible) |
valueQuantity | SΣ | 0..1 | Quantity | Vital Sign Value recorded with UCUM Binding: Vital Signs Units (required) |
id | 0..1 | string | xml:id (or equivalent in JSON) | |
extension | 0..* | Extension | Additional Content defined by implementations Slice: Unordered, Open by value:url | |
value | SΣ | 1..1 | decimal | Numerical value (with implicit precision) |
comparator | ?!Σ | 0..1 | code | < | <= | >= | > - how to understand the value Binding: QuantityComparator (required) |
unit | SΣ | 1..1 | string | Unit representation |
system | SΣI | 1..1 | uri | System that defines coded unit form Fixed Value: http://unitsofmeasure.org |
code | SΣ | 1..1 | code | Coded responses from the common UCUM units for vital signs value set. |
dataAbsentReason | SI | 0..1 | CodeableConcept | Why the component result is missing Binding: Observation Value Absent Reason (extensible) |
interpretation | 0..1 | CodeableConcept | High, low, normal, etc. Binding: Observation Interpretation Codes (extensible) | |
referenceRange | 0..* | Unknown reference to #Observation.referenceRange Provides guide for interpretation of component result | ||
Documentation for this format |
Downloads: StructureDefinition: (XML, JSON), Schema: XML Schematron
Below is an overview of the required search and read operations.
Summary of Search Criteria for StructureDefinition-au-bodyheight
none defined