This is the set of resources that conform to either of the profiles AU Core Body Temperature (http://hl7.org.au/fhir/core/StructureDefinition/au-core-bodytemp) and AU Core Body Temperature (http://hl7.org.au/fhir/core/StructureDefinition/au-core-bodytemp). E.g. what you have to deal with if you get resources conforming to one of them
Name | Flags | Card. | Type | Description & Constraints |
---|---|---|---|---|
Observation | C | 0..* | Body temperature dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. au-core-obs-02: At least value or data absent reason shall be present | |
meta | Σ | 0..1 | Meta | Metadata about the resource ele-1: All FHIR elements must have a @value or children |
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children |
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language. ele-1: All FHIR elements must have a @value or children | |
text | 0..1 | Narrative | Text summary of the resource, for human interpretation ele-1: All FHIR elements must have a @value or children | |
contained | 0..* | Resource | Contained, inline Resources | |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
identifier | Σ | 0..* | Identifier | Business Identifier for observation ele-1: All FHIR elements must have a @value or children |
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order ele-1: All FHIR elements must have a @value or children |
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event ele-1: All FHIR elements must have a @value or children |
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required) ele-1: All FHIR elements must have a @value or children |
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ?? (preferred): Codes for high level observation categories. ele-1: All FHIR elements must have a @value or children |
code | SΣ | 1..1 | CodeableConcept | Body Temperature Binding: ?? (extensible): This identifies the vital sign result type. ele-1: All FHIR elements must have a @value or children |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
coding | Σ | 2..* | Coding | Code defined by a terminology system ele-1: All FHIR elements must have a @value or children |
text | Σ | 0..1 | string | Plain text representation of the concept ele-1: All FHIR elements must have a @value or children |
subject | SΣ | 1..1 | Reference(AU Core Patient | #sd-au-core-patient-au-core-patient) | Who and/or what the observation is about ele-1: All FHIR elements must have a @value or children |
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record ele-1: All FHIR elements must have a @value or children |
encounter | SΣ | 0..1 | Reference(AU Core Encounter | #sd-au-core-encounter-au-core-encounter) | Healthcare event during which this observation is made ele-1: All FHIR elements must have a @value or children |
effective[x] | SΣC | 1..1 | dateTime | Date, and optionally time, the observation was performed ele-1: All FHIR elements must have a @value or children vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day au-core-obs-01: Date shall be at least to day |
issued | Σ | 0..1 | instant | Date/Time this version was made available ele-1: All FHIR elements must have a @value or children |
performer | SΣ | 0..* | Reference(AU Core Practitioner | AU Core PractitionerRole | AU Core Organization | AU Core Patient | AU Core RelatedPerson | #sd-au-core-practitioner-au-core-practitioner) | Who is responsible for the observation ele-1: All FHIR elements must have a @value or children |
value[x] | SΣ | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. ele-1: All FHIR elements must have a @value or children |
dataAbsentReason | S | 0..1 | CodeableConcept | Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children |
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. ele-1: All FHIR elements must have a @value or children | |
note | 0..* | Annotation | Comments about the observation ele-1: All FHIR elements must have a @value or children | |
bodySite | C | 0..1 | CodeableConcept | Observed body part Binding: ?? (preferred) ele-1: All FHIR elements must have a @value or children au-core-obs-04: If a coded body site is provided, at least one code shall be from SNOMED CT |
method | 0..1 | CodeableConcept | How it was done Binding: ?? (example): Methods for simple observations. ele-1: All FHIR elements must have a @value or children | |
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation ele-1: All FHIR elements must have a @value or children | |
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device ele-1: All FHIR elements must have a @value or children | |
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation ele-1: All FHIR elements must have a @value or children obs-3: Must have at least a low or a high or text |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
low | 0..1 | ?? | Low Range, if relevant ele-1: All FHIR elements must have a @value or children | |
high | 0..1 | ?? | High Range, if relevant ele-1: All FHIR elements must have a @value or children | |
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. ele-1: All FHIR elements must have a @value or children | |
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. ele-1: All FHIR elements must have a @value or children | |
age | 0..1 | Range | Applicable age range, if relevant ele-1: All FHIR elements must have a @value or children | |
text | 0..1 | string | Text based reference range in an observation ele-1: All FHIR elements must have a @value or children | |
hasMember | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components ele-1: All FHIR elements must have a @value or children |
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from ele-1: All FHIR elements must have a @value or children |
component | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. ele-1: All FHIR elements must have a @value or children vs-3: If there is no a value a data absent reason must be present |
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both |
code | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: ?? (extensible): This identifies the vital sign result type. ele-1: All FHIR elements must have a @value or children |
value[x] | SΣ | 0..1 | Vital Sign Value recorded with UCUM Binding: ?? (required): Common UCUM units for recording Vital Signs. ele-1: All FHIR elements must have a @value or children | |
valueQuantity | Quantity | |||
valueCodeableConcept | CodeableConcept | |||
valueString | string | |||
valueBoolean | boolean | |||
valueInteger | integer | |||
valueRange | Range | |||
valueRatio | Ratio | |||
valueSampledData | SampledData | |||
valueTime | time | |||
valueDateTime | dateTime | |||
valuePeriod | Period | |||
dataAbsentReason | S | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children |
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. ele-1: All FHIR elements must have a @value or children | |
referenceRange | 0..* | Provides guide for interpretation of component result ele-1: All FHIR elements must have a @value or children | ||
Documentation for this format |